EDA.org Mantis
Mantis Bugtracker

Viewing Issue Simple Details Jump to Notes ] Wiki ] View Advanced ] Issue History ] Print ]
ID Category Severity Date Submitted Last Update
0000597 [SystemVerilog P1800] SV-EC minor 2005-03-23 17:44 2007-01-15 13:43
Reporter Steven Sharp View Status public  
Assigned To
Priority normal Resolution duplicate  
Status closed   Product Version
Summary 0000597: Unnamed clocking blocks in BNF
Description The BNF for a clocking block allows the name of a clocking block to be optional. It is unclear how one would reference inputs and outputs defined within the clocking block if it is not named as all references too it are through the BNF production of hierarchical_identifier.

This may just be an issue with the BNF, where this combination is allowed by the grammar (to keep it simple) but is disallowed by some other rule. If this other rule already appears somewhere, then this is not a problem. Otherwise it needs to be added, or the BNF changed.
Additional Information CLOSED January 8th 2007 sv-ec meeting. unanimously
duplicate of 1325
Tags No tags attached.
Type Errata
Attached Files

- Relationships
duplicate of 0001325closedNeil Korpusik Clarify references to items declared in unnamed clocking blocks. 

There are no notes attached to this issue.

- Issue History
Date Modified Username Field Change
2005-03-23 17:44 Steven Sharp New Issue
2005-03-23 17:44 Steven Sharp Type => Errata
2007-01-15 13:43 mehdi_mohtashemi Relationship added duplicate of 0001325
2007-01-15 13:43 mehdi_mohtashemi Status new => closed
2007-01-15 13:43 mehdi_mohtashemi Resolution open => duplicate
2007-01-15 13:43 mehdi_mohtashemi Additional Information Updated


Mantis 1.1.7[^]
Copyright © 2000 - 2008 Mantis Group
Powered by Mantis Bugtracker